Inspection Detail
Inspection: 18687624 - San Juan Racing Association, Inc.
Inspection Information - Office: Pr-E-Carolina 0257230
Site Address:
San Juan Racing Association, Inc.
Carr. #3 Km. 15.3, Hipodromo El Comandante
Canovanas, PR 00629
Mailing Address:
P.O. Box 29000, 65 Inf. Station, Rio Piedras, PR 00929
Union Status: Union
SIC:7948
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/06/1988
Emphasis:
Case Closed: 06/07/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360347975 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $630 | $0 | $0 | $0 | $0 | $630 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 6A0001 | 01/24/1989 | 01/28/1989 | $630 | $630 | $0 | 01/31/1989 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
A OVERHEAD POWER LINE HAD BEEN CUT AND WAS LYING ON THE GROUND. AN EMPLOYEE WAS ELECTROCUTED WHEN HIS LEFT HAND CONTACTED THE POWER LINE.
Keywords: E GI V, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 18687624 | Fatality | Electric Shock | Occupation not reported |