Powered by GoogleTranslate

Inspection Detail

Inspection: 18560904 - Draper Paint Company

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 18560904
Report ID: 0453710
Date Opened: 08/30/1991

Site Address:
Draper Paint Company
320 Federal Place
Greensboro, NC 27401

Mailing Address:
3600 Old Climax Rd., Climax, NC 27233

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/10/1991

Emphasis:

Case Closed: 12/09/1991


Related Activity
Type Activity Nr Safety Health
Accident 360263917
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $1,980 $0 $0 $0 $0 $1,980
Current Penalty $1,980 $0 $0 $0 $0 $1,980
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 I04 10/18/1991 10/24/1991 $660 $660 $0 -  
2. 01002 Serious 19260451 I08 10/18/1991 10/24/1991 $660 $660 $0 -  
3. 01003 Serious 19260451 I08 10/18/1991 10/24/1991 $660 $660 $0 -  

Investigation Summary

Investigation Nr: 170063283
Event: 08/30/1991
One employee killed and one injured in scaffold fall

Employees #1 and #2 and their foreman were ascending the side of a 5-story office building on a Werner model #2624, 500 lb capacity, 2-point suspension scaffold to commence painting. The power to the two hoist motors went dead with the scaffold approximately 22 ft above the asphalt parking lot. The foreman left the scaffold to restore power. Employees #1 and #2 remained on the scaffold to pull up power cords to plug into an alternate power source. Employees #1 and #2 untied themselves from their lifelines and the foreman tied the power cord to one lifeline. Employees #1 and #2 pulled the cord up to the scaffold. The foreman went to the third floor to plug in that power cord. Employees #1 and #2 handed the cord to the foreman through a window and the foreman plugged it into an outlet. The roof anchorage for the scaffold gave way because the brick masonry parapet collapsed and one end of the scaffold fell to the ground along with Employees #1 and #2. Employee #1 was killed and Employee #2 sustained injuries to his head and right leg and torso. The parapet clamp on the west end of the scaffold was not secured to the structure, and Employees #1 and #2 were not secured to lifelines.

Keywords: UNSECURED, WORK RULES, BRICK, TIE-OFF, ROOF, LIFELINE, COLLAPSE, CONSTRUCTION, TWO PT SUSP SCAFFOLD, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18560904 Fatality Other Painters, construction and maintenance
2 18560904 Hospitalized injury Fracture Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.