Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 18555110
Report ID: 0453710
Date Opened: 09/19/1991

Site Address:
Sportswear Express, Inc.
801 North Main St. Nw
Lenoir, NC 28645

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2339

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/19/1991

Emphasis:

Case Closed: 12/22/1992


Related Activity
Type Activity Nr Safety Health
Accident 360489660
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 2 4 6
Initial Penalty $1,680 $0 $0 $400 $0 $2,080
Current Penalty $1,680 $0 $0 $400 $0 $2,080
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100178 Q07 11/25/1991 12/02/1991 $880 $880 $0 -  
2. 01002A Serious 19100215 A02 11/25/1991 12/13/1991 $800 $800 $0 -  
3. 01002B Serious 19100215 B09 11/25/1991 12/13/1991 $0 $0 $0 -  
4. 02001 Other 7B0302 A 11/25/1991 12/13/1991 $400 $400 $0 -  
5. 02002 Other 19101200 E01 11/25/1991 12/28/1991 $0 $0 $0 -  
6. 02003 Other 19101200 F05 11/25/1991 12/13/1991 $0 $0 $0 -  
7. 02004 Other 19101200 G01 11/25/1991 12/28/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170072995
Event: 09/17/1991
Eight employees ill from carbon monoxide exhaust

A propane-powered forklift was used to unload cut fabric from a truck trailer. Before the fabric could be unloaded, other goods in the trailer had to be moved and then reloaded in order to access the fabric. This added time to unload resulted in the forklift running longer than usual. Sewing machine operators in the adjacent area were exposed to propane from a leaking fuel line and carbon monoxide from the exhaust. Employees #1 through #8 developed severe headaches and one employee passed out. Emergency medical services were called and the building was evacuated. Employees #1 through #8 were taken to the hospital, treated with oxygen and Tylenol, and released. Six of the injured employees returned to work the next day; the remaining two returned one day later. Tests of the forklift exhaust showed high levels of carbon monoxide due to improper fuel-to-oxygen ratio.

Keywords: LEAK, UNCONSCIOUSNESS, HEADACHE, INDUSTRIAL TRUCK, EXHAUST FUMES, OFF LOADING, PROPANE, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
2 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
3 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
4 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
5 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
6 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
7 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
8 18555110 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.