Powered by GoogleTranslate

Inspection Detail

Inspection: 18553917 - Hepaco Incorporated

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 18553917
Report ID: 0453710
Date Opened: 10/22/1991

Site Address:
Hepaco Incorporated
5313 Old Dowd Road
Charlotte, NC 28208

Mailing Address:
P. O. Box 26308, Charlotte, NC 28221

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 10/22/1991

Emphasis: L:Asbestos

Case Closed: 10/22/1991


Related Activity
Type Activity Nr Safety Health
Accident 360489777

Investigation Summary

Investigation Nr: 942615
Event: 10/14/1991
Employee singed by acetylene cylinder fire

Employee #1 was at mid-dock in an acetylene generating plant discharging acetylene from leaking cylinders. After opening the sixth cylinder, Employee #1 set the cylinder down and it ignited. The flames from this cylinder ignited the other cylinders. Employee #1 sustained only singed hair on both arms and one eyebrow.

Keywords: HAIR, CYLINDER, ACETYLENE, EXPLOSION, FURNACE, FIRE, CONSTRUCTION, ARM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18553917 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close