Inspection Detail
Inspection: 18528364 - Mcdowell Roofing And Maintenance Company
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Mcdowell Roofing And Maintenance Company
1311 Morehead Avenue
Durham, NC 27707
Mailing Address:
110 Muldee Street, Durham, NC 27703
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/24/1989
Emphasis:
Case Closed: 02/14/1989
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360260723 |
Investigation Summary
AN EMPLOYEE WAS REPLACING THE ROOF OF A CHURCH. HE HAD JUST DESCENDED AN EXTENSION LADDER. THE EMPLOYER'S NORMAL PRACTICE WAS TO LOWER THE LADDER AND THEN LAY IT ON ITS SIDE. THE EMPLOYEE DID NOT FOLLOW THIS PRACTICE. INSTEAD, HE APPARENTLY RAISED THE LADDER AND PULLED IT BACKWARDS INTO A 7200-VOLT OVERHEAD POWER LINE THAT WAS ABOUT 25 FEET ABOVE THE GROUND. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: EXTENSION LADDER, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, E GI IB
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18528364 | Fatality | Electric Shock | Roofers |
Translate