Powered by GoogleTranslate

Inspection Detail

Inspection: 1848993 - Atec Associates Inc Of Virginia Inc

Inspection Information - Office: Norfolk Area Office

 

Inspection Nr: 1848993
Report ID: 0316110
Date Opened: 01/11/1985

Site Address:
Atec Associates Inc Of Virginia Inc
Regules & Talos Ade Dam Neck Naval Station
Virginia Beach, VA 23246

Mailing Address:
7611 Sewells Point Road, Norfolk, VA 23513

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/17/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/05/1985


Related Activity
Type Activity Nr Safety Health
Accident 360654867
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $350 $0 $0 $0 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260600 A16 01/31/1985 02/05/1985 $350 $350 $0 -  

Investigation Summary

Investigation Nr: 14508535
Event: 01/10/1985
Electric shock - contact through core sampling rod

Three employees were taking earth boring samples using a core sampling rig with a 6.7-meter-high tower. As they removed the sampling rod (four 3.05-meter-long rods connected together) from the ground, the rod struck a 4160-volt overhead electric power line that was 10 meters above the ground. This caused two of the employees to be electrocuted and the other employee to be seriously injured.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL POLE, DRILL RIG--NON-OIL, ELECTRIC SHOCK, E GI IC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1848993 Fatality Electric Shock Occupation not reported
2 1848993 Fatality Electric Shock Occupation not reported
3 1848993 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.