Inspection Detail
Inspection: 1848993 - Atec Associates Inc Of Virginia Inc
Inspection Information - Office: Norfolk Area Office
Site Address:
Atec Associates Inc Of Virginia Inc
Regules & Talos Ade Dam Neck Naval Station
Virginia Beach, VA 23246
Mailing Address:
7611 Sewells Point Road, Norfolk, VA 23513
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/17/1985
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/05/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360654867 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $350 | $0 | $0 | $0 | $0 | $350 |
| Current Penalty | $350 | $0 | $0 | $0 | $0 | $350 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260600 A16 | 01/31/1985 | 02/05/1985 | $350 | $350 | $0 | - |
Investigation Summary
Three employees were taking earth boring samples using a core sampling rig with a 6.7-meter-high tower. As they removed the sampling rod (four 3.05-meter-long rods connected together) from the ground, the rod struck a 4160-volt overhead electric power line that was 10 meters above the ground. This caused two of the employees to be electrocuted and the other employee to be seriously injured.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL POLE, DRILL RIG--NON-OIL, ELECTRIC SHOCK, E GI IC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1848993 | Fatality | Electric Shock | Occupation not reported | ||
| 2 | 1848993 | Fatality | Electric Shock | Occupation not reported | ||
| 3 | 1848993 | Hospitalized injury | Electric Shock | Occupation not reported |