Inspection Detail
Inspection: 18482398 - Lennox Baker Childrens Hospital
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Lennox Baker Childrens Hospital
3000 Erwin Rd.
Durham, NC 27705
Mailing Address:
Post Office Box 3120, Durham, NC 27710
Union Status: NonUnion
SIC:8069
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/02/1989
Emphasis:
Case Closed: 09/12/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360260970 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 7B0305 D | 05/02/1989 | 05/05/1989 | $0 | $0 | $0 | - |
Investigation Summary
An oxygen regulator ignited and burned as Employee #1 was turning on the regulator. The brass housing of the regulator and the internal parts served as the fuel in the oxygen rich atmosphere. Employee #1 suffered second-degree burns on his arm.
Keywords: BURN, OXYGEN, REGULATOR VALVE, FIRE, ARM
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 18482398 | Hospitalized injury | Burn/Scald(Heat) | Nursing aides, orderlies, and attendants |