Inspection: 18402164 - Scruggs Inc
Inspection Information - Office: Tennessee Osha Knoxville Office - Safety
Site Address:
Scruggs Inc
3004 Industrial Park
Knoxville, TN 37921
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5046
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/12/1986
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/12/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360777668 |
Investigation Summary
AN ELECTRONIC EQUIPMENT REPAIRER HAD SERVICED A 240-VOLT LITTON COMMERCIAL MICROWAVE OVEN (MODEL NUMBER 70-80), AND HE WAS PERFORMING A HIGH VOLTAGE TEST ON IT. HE WAS USING A NEW EMCO PHV-1 HIGH VOLTAGE PROBE THAT HAD BEEN PURCHASED BY THE EMPLOYER 1 OR 2 DAYS EARLIER. THE REPAIRER WAS WORKING ALONE, BUT THERE WAS ANOTHER EMPLOYEE IN THE VICINITY. THE REPAIRER MADE TWO ATTEMPTS TO MEASURE VOLTAGE, BUT THE METER DID NOT REGISTER ANY VOLTAGE. ON THE THIRD ATTEMPT, HE RECEIVED AN ELECTRIC SHOCK AND YELLED TO HIS COWORKER TO "GET ME OFF OF THIS". THE EMPLOYEE RECEIVED BURNS ON BOTH HANDS; HE HAD BEEN HOLDING THE GROUNDED METER IN HIS RIGHT HAND AND HAD APPARENTLY CONTACTED AN ENERGIZED PART WITH HIS LEFT HAND.
Keywords: BURN, E GI II, ELEC PROTECT EQUIP, ELECTRICAL, TEST EQUIPMENT, ELECTRIC SHOCK, MICROWAVE OVEN
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 18402164 | Hospitalized injury | Electric Shock | Electronic repairers, communica. & indus. equip. |