Inspection Detail
Inspection: 18346825 - Westinghouse Electric Corp./Pensacola Division
Inspection Information - Office: Jacksonville Area Office
Site Address:
Westinghouse Electric Corp./Pensacola Division
8301 Scenic Highway
Pensacola, FL 32514
Mailing Address:
, , 00000
Union Status: Union
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/13/1991
Emphasis:
Case Closed: 05/06/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360709893 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 10 | 10 | ||||
| Current Violations | 10 | 10 | ||||
| Initial Penalty | $25,875 | $0 | $0 | $0 | $0 | $25,875 |
| Current Penalty | $15,525 | $0 | $0 | $0 | $0 | $15,525 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100028 J01 | 04/03/1991 | 04/24/1991 | $1,125 | $1,875 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100028 J03 | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 3. | 01002A | Serious | 19100132 A | 04/02/1991 | 04/05/1991 | $2,250 | $3,750 | $0 | I - Informal Settlement | ||
| 4. | 01002B | Serious | 19100134 E03 III | 04/03/1991 | 04/05/1991 | $0 | $0 | $0 | - | ||
| 5. | 01003A | Serious | 19100134 B05 | 04/03/1991 | 04/24/1991 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 6. | 01003B | Serious | 19100134 E04 | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 7. | 01003C | Serious | 19100134 F01 | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 8. | 01003D | Serious | 19100134 F02 I | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 9. | 01003E | Serious | 19100134 F02 II | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 10. | 01003F | Serious | 19100134 F02 IV | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 11. | 01004A | Serious | 19100134 E05 | 04/03/1991 | 04/24/1991 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 12. | 01004B | Serious | 19100134 E05 I | 04/03/1991 | 04/24/1991 | $0 | $0 | $0 | - | ||
| 13. | 01005 | Serious | 19100252 A02 I | 04/03/1991 | 04/05/1991 | $2,250 | $3,750 | $0 | I - Informal Settlement | ||
| 14. | 01006 | Serious | 19100252 A02 II | 04/03/1991 | 04/05/1991 | $2,250 | $3,750 | $0 | I - Informal Settlement | ||
| 15. | 01007 | Serious | 19100252 A02 VII | 04/03/1991 | 04/05/1991 | $2,250 | $3,750 | $0 | I - Informal Settlement | ||
| 16. | 01008 | Serious | 19100252 B04 IV | 04/03/1991 | 04/05/1991 | $2,250 | $3,750 | $0 | I - Informal Settlement | ||
| 17. | 01009 | Serious | 19101200 E01 | 04/03/1991 | 04/24/1991 | $675 | $1,125 | $0 | I - Informal Settlement | ||
| 18. | 01010 | Serious | 19101200 H | 04/03/1991 | 04/24/1991 | $675 | $1,125 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was one of two employees performing an arc welding metal spray procedure inside a continuous digester at a paper mill. The work was being performed on a scaffold 50 feet from the top of the vessel, which had a vertical height of 155 feet and an inside diameter of 14 feet. A fire started on a tarp below the work scaffold. Because the employees were not connected to lifelines, they exited from the vessel by hanging onto a boatswain's chair as it was lifted to the top. Employee #1 fell from the ascending chair. He died of hyperthermia before rescue workers could reach him.
Keywords: BOSUN CHAIR, LIFELINE, CONFINED SPACE, WORK RULES, FIRE, FALL, FALL PROTECTION, ARC WELDING, HIGH TEMPERATURE, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18346825 | Fatality | Heat Exhaustion | Occupation not reported |
Translate