Inspection: 18338020 - L.E. Schwartz & Son, Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 18338020
Report ID: 0418100
Date Opened: 08/31/1989

Site Address:
L.E. Schwartz & Son, Inc.
Ykk Usa, Inc. 4234 Ocmulgee East Blvd
Macon, GA 31217

Mailing Address:
P.O. Box 4223, Macon, GA 31208

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/31/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/06/1989


Related Activity
Type Activity Nr Safety Health
Accident 360374979
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 4 4
Initial Penalty $2,680 $0 $0 $0 $0 $2,680
Current Penalty $1,340 $0 $0 $0 $0 $1,340
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 09/25/1989 09/28/1989 $200 $350 $0 I - Informal Settlement  
2. 01002 Serious 19260403 E 09/25/1989 09/28/1989 $420 $420 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Serious 19260404 B01 III 09/25/1989 09/28/1989 $420 $420 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19260404 F06 09/25/1989 09/28/1989 $420 $420 $0 I - Informal Settlement Citation has been deleted.
5. 01005 Serious 19260405 A02 IIJ 09/25/1989 09/28/1989 $350 $350 $0 I - Informal Settlement Citation has been deleted.
6. 01006 Serious 19260556 B02 V 09/25/1989 09/28/1989 $420 $420 $0 I - Informal Settlement Citation has been deleted.
7. 01007A Serious 19260403 E 09/25/1989 09/28/1989 $420 $0 $0 Q - National Office Adjustment  
8. 01007B Serious 19260404 B01 III 09/25/1989 09/28/1989 $0 $0 $0 -  
9. 01008A Serious 19260404 F06 09/25/1989 09/28/1989 $420 $0 $0 Q - National Office Adjustment  
10. 01008B Serious 19260405 A02 IIJ 09/25/1989 09/28/1989 $0 $0 $0 -  
11. 01009 Serious 19260556 B02 09/25/1989 09/28/1989 $300 $300 $0 -  

Investigation Summary

Investigation Nr: 14336978
Event: 08/30/1989
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED CONDUCTOR

A sheet metal helper was working from an aerial work platform, setting metal screws with a 6-millimeter (0.25-inch) portable electric drill. The power supply cord on the drill had apparently been replaced, as it was not approved for hard usage. Additionally, the attachment plug was missing the pin for the equipment grounding conductor, and the conductors in the cord were exposed. The employee might have contacted one of the conductors and was electrocuted. The employee also had an asthma condition, which could have contributed to his death.

Keywords: RESPIRATORY, E GI V, ELEC INSULATION, ELECTRICAL, ELECTROCUTED, RESPIRATORY TRACT, ELECTRIC CONDUCTOR, ELECTRIC CORD, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18338020 Fatality Asphyxia Sheetmetal duct installers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.