Inspection Detail
Inspection: 18080093 - Central Florida Underground, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Central Florida Underground, Inc.
Banana Lake Road
Lake Mary, FL 32746
Mailing Address:
990 Miller Drive, Altamonte Springs, FL 32701
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Health
Close Conference: 01/08/1990
Emphasis:
Case Closed: 03/01/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360453567 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 2 | 2 | 8 | ||
| Current Violations | 4 | 2 | 2 | 8 | ||
| Initial Penalty | $3,600 | $20,000 | $0 | $0 | $0 | $23,600 |
| Current Penalty | $3,600 | $14,000 | $0 | $0 | $0 | $17,600 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Willful | 5A0001 | 01/11/1990 | 01/14/1990 | $7,000 | $10,000 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Willful | 19260021 B06 I | 01/11/1990 | 01/14/1990 | $7,000 | $10,000 | $0 | I - Informal Settlement | ||
| 3. | 02001 | Serious | 19260059 E01 | 01/11/1990 | 02/14/1990 | $900 | $900 | $0 | - | ||
| 4. | 02002 | Serious | 19260059 E01 I | 01/11/1990 | 02/14/1990 | $900 | $900 | $0 | - | ||
| 5. | 02003 | Serious | 19260059 G01 | 01/11/1990 | 02/14/1990 | $900 | $900 | $0 | - | ||
| 6. | 02004 | Serious | 19260059 H01 | 01/11/1990 | 02/14/1990 | $900 | $900 | $0 | - | ||
| 7. | 03001 | Other | 19040002 A | 01/11/1990 | 01/22/1990 | $0 | $0 | $0 | - | ||
| 8. | 03002 | Other | 19040005 C | 01/11/1990 | 01/22/1990 | $0 | $0 | $0 | - |
Investigation Summary
This event occurred at a sealed confined space which contained pipe which had been painted the previous day. This space was a twelve foot diameter, thirty foot deep wet well, which was part of a new, unused sewer lift station. The well contained approximately five feet of accumulated water. The paint contained xylene. The well was not ventilated prior to entrance. The air was not tested for oxygen content, air contaminants, or flammable explosive vapors. Employee #1 started a descent to install a valve on a stubble pipe when he was overcome by the xylene vapors and fell from the ladder into the accumulated water. Employees #2 and #3 radioed for help and then descended into the well to attempt a rescue. Both Employees #2 and #3 were also overcome by the vapors and fell into the water. Employees #1 and #2 died at the scene. Employee #3 was rescued by paramedics and recovered
Keywords: SEWER, LUNG, ASPHYXIATED, XYLENE, WELL, CHEMICAL VAPOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18080093 | Fatality | Asphyxia | Occupation not reported | ||
| 2 | 18080093 | Fatality | Asphyxia | Occupation not reported | ||
| 3 | 18080093 | Non Hospitalized injury | Asphyxia | Occupation not reported |