Powered by GoogleTranslate

Inspection Detail

Inspection: 18008441 - Hills Quality Plumbing, Inc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 18008441
Report ID: 0419700
Date Opened: 05/07/2002

Site Address:
Hills Quality Plumbing, Inc.
4620 South Peninsula Drive
Ponce Inlet, FL 32127

Mailing Address:
1609 Ridgewood Ave, Holly Hill, FL 32117

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/29/2002

Emphasis: L:Flcare, S:Construction Fatalities

Case Closed: 11/29/2002


Related Activity
Type Activity Nr Safety Health
Accident 101352276
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $6,100 $0 $0 $1,500 $0 $7,600
Current Penalty $3,950 $0 $0 $850 $0 $4,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101200 E01 10/16/2002 11/02/2002 $350 $600 $0 I - Informal Settlement  
2. 01001B Serious 19101200 F05 I 10/16/2002 10/21/2002 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19101200 F05 II 10/16/2002 10/21/2002 $0 $0 $0 I - Informal Settlement  
4. 01001D Serious 19101200 H01 10/16/2002 10/21/2002 $0 $0 $0 I - Informal Settlement  
5. 01002 Serious 19260021 B02 10/16/2002 11/02/2002 $3,200 $4,900 $0 I - Informal Settlement  
6. 01003A Serious 19260350 A06 10/16/2002 10/21/2002 $400 $600 $0 I - Informal Settlement  
7. 01003B Serious 19260350 A12 10/16/2002 10/21/2002 $0 $0 $0 I - Informal Settlement  
8. 02001 Other 19040039 A 10/16/2002 10/21/2002 $850 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201351814
Event: 05/03/2002
Employee killed by heat exhaustion

At approximately 1:37 p.m. on May 4, 2002, Employee #1, a plumber's helper, collapsed while cleaning debris from around a townhouse building site. Earlier that day, Employee #1 helped lay copper pipes in the ground and around 11 a.m. complained of stomach pains. The pipe laying and the debris cleaning were both done in the sun. Employee #1 was transported by ambulance to the hospital where he died. Reportedly, his core body temperature was 108 degrees F. The medical examiner listed the cause of death as complications of hyperthermia. On the day of the incident, the National Weather Service reported the following for the Daytona Beach Airport at approximately 1:50 p.m.: Winds 9 MPH South; Relative Humidity 47; Temperature 92 deg F.; Heat Index 97 deg F.; Dew Point 69; No obstructions and mostly sunny.

Keywords: INSTALLING, PIPE, PLUMBING, HEAT EXHAUSTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18008441 Fatality Heat Exhaustion Plumber, pipefitter and steamfiter apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close