Inspection Detail
Note: The following inspection has not been indicated as closed. OSHA citation items will be posted 30 (thirty) days after the employer receives the citation(s), except in cases of significant public interest. Posted citation items reflect any amendments to citations that are the result of a prompt settlement, which OSHA encourages. Employers and employee representatives will continue to receive copies of the citation(s) upon issuance.
Inspection: 1797284.015 - Clean Harbors Environmental Services Inc.
Inspection Information - Office: Cleveland Area Office
Site Address:
Clean Harbors Environmental Services Inc.
1672 Highland Rd.
Twinsburg, OH 44087
Mailing Address:
256 W. Northbend Rd., Cincinnati, OH 45216
Union Status: NonUnion
SIC:
NAICS: 221320/Sewage Treatment Facilities
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/02/2025
Emphasis: L:Tankclean5
Case Closed:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 2250245 | ||
Inspection | 1797378 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 3 | 10 | |||
Current Violations | 7 | 3 | 10 | |||
Initial Penalty | $106,396 | $496,542 | $0 | $0 | $0 | $602,938 |
Current Penalty | $106,396 | $496,542 | $0 | $0 | $0 | $602,938 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100134 D03 I | 07/08/2025 | 08/01/2025 | $11,823 | $11,823 | $0 | 07/25/2025 | C - Contested | |
2. | 01002 | Serious | 19100146 D04 I | 07/08/2025 | 08/01/2025 | $11,823 | $11,823 | $0 | 07/25/2025 | C - Contested | |
3. | 01003A | Serious | 19100146 D09 | 07/08/2025 | 08/01/2025 | $16,550 | $16,550 | $0 | 07/25/2025 | C - Contested | |
4. | 01003B | Serious | 19100146 J04 | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
5. | 01003C | Serious | 19100146 K01 IV | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
6. | 01003D | Serious | 19100146 K01 V | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
7. | 01004 | Serious | 19100146 E03 | 07/08/2025 | 08/01/2025 | $16,550 | $16,550 | $0 | 07/25/2025 | C - Contested | |
8. | 01005A | Serious | 19100146 H01 | 07/08/2025 | 08/01/2025 | $16,550 | $16,550 | $0 | 07/25/2025 | C - Contested | |
9. | 01005B | Serious | 19100146 I01 | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
10. | 01006 | Serious | 19100146 J02 | 07/08/2025 | 08/01/2025 | $16,550 | $16,550 | $0 | 07/25/2025 | C - Contested | |
11. | 01007 | Serious | 19100146 K02 IV | 07/08/2025 | 08/01/2025 | $16,550 | $16,550 | $0 | 07/25/2025 | C - Contested | |
12. | 02001 | Willful | 19100146 D03 IV | 07/08/2025 | 08/01/2025 | $165,514 | $165,514 | $0 | 07/25/2025 | C - Contested | |
13. | 02002A | Willful | 19100146 D03 VI | 07/08/2025 | 08/01/2025 | $165,514 | $165,514 | $0 | 07/25/2025 | C - Contested | |
14. | 02002B | Willful | 19100146 D05 I | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
15. | 02002C | Willful | 19100146 D05 II | 07/08/2025 | 08/01/2025 | $0 | $0 | $0 | 07/25/2025 | C - Contested | |
16. | 02003 | Willful | 19100146 K03 | 07/08/2025 | 08/01/2025 | $165,514 | $165,514 | $0 | 07/25/2025 | C - Contested |
Investigation Summary
At approximately 9:34 a.m. on January 10, 2025, an employee was directed to enter a 23,737-gallon rail tank car containing residues of PCBs and transformer oil to obtain wipe samples of the interior surfaces. The rail tank car was a permit-required confined space. The employee wore a full-face air-purifying respirator, chemical protective suit, boots, and gloves. Shortly after descending the temporary ladder to the tank bottom, the employee slowed, then fell forward and became unresponsive at the base of the ladder. Prior to entry, the tank car had not been mechanically ventilated, atmospheric monitoring was insufficient and not performed during entry, and non-entry rescue systems were inadequate-the tripod lacked a mechanical winch or lifeline, and the entrant was not wearing a full-body rescue harness. Oxygen levels inside the tank were as low as 5%, resulting in fatal asphyxiation.
Keywords: Asphyxiated, Confined Space, Lack of oxygen, Oxygen, Oxygen Deficiency, Respirator, Respiratory, Respiratory Tract, Tank, Tripod, Unresponsive
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1797284.015 | 35 | M | Fatality |