Powered by GoogleTranslate

Inspection Detail

Case Status: OPEN

Note: The following inspection has not been indicated as closed. OSHA citation items will be posted 30 (thirty) days after the employer receives the citation(s), except in cases of significant public interest. Posted citation items reflect any amendments to citations that are the result of a prompt settlement, which OSHA encourages. Employers and employee representatives will continue to receive copies of the citation(s) upon issuance.

Inspection: 1795669.015 - Acwoodcraft, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 1795669.015
Report ID: 0420600
Date Opened: 12/31/2024

Site Address:
Acwoodcraft, Inc.
5611 Easy Street
Fort Myers Beach, FL 33931

Mailing Address:
1950 Custom Drive, Fort Myers, FL 33907

Union Status: NonUnion

SIC:

NAICS: 236118/Residential Remodelers


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/31/2024

Emphasis:

Case Closed:


Related Activity
Type Activity Nr Safety Health
Accident 2246990
Case Status: OPEN
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $21,515 $0 $0 $3,547 $0 $25,062
Current Penalty $21,515 $0 $0 $3,547 $0 $25,062
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A01 06/20/2025 07/17/2025 $16,550 $16,550 $0 07/18/2025 C - Contested  
2. 01002 Serious 19260416 A03 06/20/2025 07/17/2025 $4,965 $4,965 $0 07/18/2025 C - Contested  
3. 02001 Other 19040039 A01 06/20/2025 $3,547 $3,547 $0 07/18/2025 C - Contested  

Investigation Summary

Investigation Nr: 173061.015
Event: 12/30/2024
Employee is electrocuted while installing dryer vent and sus

At 3:30 p.m. on December 30, 2024, Employee #1 was working under an 18-foot tall platform installing a dryer vent when he began spasming and called for help. Coworkers pulled him out and found blood in his mouth. He was transported to the hospital but was pronounced dead about an hour later. The cause of injury was electrocution from electricity associated with the dryer.

Keywords: Blood, Dryer, Electrical, Electrocuted, Installing, Vent, Venting

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1795669.015 41 M Fatality Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close