Powered by GoogleTranslate

Inspection Detail

Inspection: 17878711 - Burke Scaffolding Co.

Inspection Information - Office: Manhattan Area Office

 

Inspection Nr: 17878711
Report ID: 0215000
Date Opened: 12/31/1990

Site Address:
Burke Scaffolding Co.
Arthur Kill Generating Station Victory Blvd.
Staten Island, NY 07072

Mailing Address:
90 Commerce Road, Carlstadt, NJ 07072

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/13/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/01/1993


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 4 4
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $4,000 $0 $0 $0 $0 $4,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 J - ALJ Decision  
2. 01002 Serious 19260020 B02 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 J - ALJ Decision  
3. 01003 Serious 19260021 B02 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 R - Review Commission Citation has been deleted.
4. 01004 Serious 19260451 A02 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 J - ALJ Decision  
5. 01005 Serious 19260451 A03 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 R - Review Commission Citation has been deleted.
6. 01006 Serious 19260451 A15 03/21/1991 03/24/1991 $1,000 $1,000 $0 04/11/1991 J - ALJ Decision  

Investigation Summary

Investigation Nr: 14552822
Event: 12/31/1990
CONSTRUCTION EMPLOYEES INJURED WHEN SCAFFOLD COLLAPSED

A KWIKSTAGE MODULAR FRAME SCAFFOLDING SYSTEM WAS ERECTED BY THE BURKE SCAFFOLDING COMPANY OF CARLSTADT, NEW JERSEY INSIDE BOILER #30 AT A CON EDISON OF NEW YORK POWER PLANT. THE SCAFFOLDING WAS COMPOSED OF 2 INCH METAL POLE UPRIGHTS FASTENED TO THE HORIZONTAL MEMBERS BY INSERTING FIXED WEDGES OF THE HORIZONTAL MEMBERS INTO THE "V" PRESSINGS ON THE UPRIGHTS. THESE INTERLOCKING COMPONENTS FORMED BAYS WHICH WERE ABOUT 8 FEET LONG, 6 FEET 6 INCHES HIGH AND 4 FEET AND 8 FEET IN WIDTH. THE SCAFFOLD, TIERED TO ABOUT 100 FEET, HAD A "DANCE FLOOR" ERECTED THEREON. FIVE ADDITIONAL 45 FOOT FREESTANDING TOWERS WERE ALSO ERECTED. EACH TOWER OF KWIKSTAGE SCAFFOLD WAS 8 FEET LONG, 6 FEET 6 INCHES HIGH AND 4 FEET WIDE AND HAD 11 TIERED BAYS. MORE THAN 9 EMPLOYEES WERE RENOVATING BOILER TUBING WHEN THE SCAFFOLD COLLAPSED. FIVE EMPLOYEES WERE HOSPITALIZED WITH INJURIES.

Keywords: COLLAPSE, CONSTRUCTION, FALL, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 17878711 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.