Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1768298.015 - Marcone Group, Inc.

Inspection Information - Office: Albany Area Office

 

Inspection Nr: 1768298.015
Report ID: 0213100
Date Opened: 08/13/2024

Site Address:
Marcone Group, Inc.
15 Industrial Park Road
Albany, NY 12206

Mailing Address:
15 Industrial Park Road, Albany, NY 12206

Union Status: NonUnion

SIC:

NAICS: 493110/General Warehousing and Storage


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/13/2024

Emphasis: N:Warehouse23

Case Closed: 02/05/2025


Related Activity
Type Activity Nr Safety Health
Accident 2199414
Case Status: CLOSED

Investigation Summary

Investigation Nr: 169196.015
Event: 08/12/2024
Employee suffers fatal cardiac arrest after parking forklift

At 2:10 p.m. on August 12, 2024, a forklift operator (Employee #1) had just parked a forklift, a Crown "stand up reach truck" series S700 side-shifter, at the end of his shift. As the employee stepped away from the forklift, he collapsed onto the concrete floor. The employee suffered cardiac arrest and was later pronounced dead.

Keywords: Blunt force, Blunt force trauma, Cardiac Arrest, Concrete, Concrete Floor, Forklift, Parking, Stand-Up Forklift, Unconsciousness, Unresponsive

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1768298.015 59 M Fatality
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.