Powered by GoogleTranslate

Inspection Detail

Inspection: 17626847 - J. C. B. International Corp.

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 17626847
Report ID: 0214500
Date Opened: 03/21/1991

Site Address:
J. C. B. International Corp.
99 Route #17 North
Maywood, NJ 07608

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5064

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/21/1991

Emphasis:

Case Closed: 08/15/1991


Related Activity
Type Activity Nr Safety Health
Accident 360660757
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 9 9
Current Violations 9 9
Initial Penalty $8,250 $0 $0 $0 $0 $8,250
Current Penalty $4,250 $0 $0 $0 $0 $4,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100157 C01 04/11/1991 04/29/1991 $250 $450 $0 I - Informal Settlement  
2. 01002 Serious 19100157 E03 04/11/1991 04/29/1991 $250 $450 $0 I - Informal Settlement  
3. 01003 Serious 19100334 A02 I 04/11/1991 04/29/1991 $750 $1,500 $0 I - Informal Settlement  
4. 01004 Serious 19100334 A03 III 04/11/1991 04/29/1991 $750 $1,500 $0 I - Informal Settlement  
5. 01005 Serious 19100335 A02 I 04/11/1991 05/14/1991 $750 $1,500 $0 I - Informal Settlement  
6. 01006 Serious 19100335 B01 04/11/1991 05/14/1991 $750 $1,500 $0 I - Informal Settlement  
7. 01007 Serious 19101200 E01 04/11/1991 05/14/1991 $250 $450 $0 I - Informal Settlement  
8. 01008 Serious 19101200 G01 04/11/1991 05/14/1991 $250 $450 $0 I - Informal Settlement  
9. 01009 Serious 19101200 H 04/11/1991 05/14/1991 $250 $450 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14492136
Event: 03/20/1991
ELECTRIC SHOCK - CONTACT WITH LIVE PARTS THROUGH HAND TOOL

A SERVICE AND REPAIR TECHNICIAN WAS WORKING ON A MICROWAVE OVEN (PANASONIC, SERIAL NUMBER SNAW916100322) AT A WORKBENCH. THE EMPLOYEE WAS MAKING A CONNECTION ON A HIGH VOLTAGE TRANSFORMER (2500 TO 3000 VOLTS) USING STANDARD 5-INCH-LONG NEEDLE NOSE PLIERS. HE APPARENTLY CONTACTED AN ENERGIZED PART ABOUT 5/8 INCHES AWAY FROM WHERE HE WAS WORKING. THE EMPLOYEE WAS ELECTROCUTED. BURNS WERE FOUND ON HIS FINGERS AND HANDS AND ON HIS UPPER ABDOMEN.

Keywords: ELEC PROTECT EQUIP, E GI IV, ELECTRICAL, INSULATED TOOL, ELECTROCUTED, LOCKOUT, HAND TOOL, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 17626847 Fatality Electric Shock Household appliance and power tool repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close