Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1757344.015 - Geovert

Inspection Information - Office: Wyoming Department Of Workforce Services - Osha Division

 

Inspection Nr: 1757344.015
Report ID: 0855610
Date Opened: 06/20/2024

Site Address:
Geovert
Fremont Canyon Road
Alcova, WY 82620

Mailing Address:
2780 Industrial Lane, Broomfield, CO 80020

Union Status: NonUnion

SIC:

NAICS: 115310/Support Activities for Forestry


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/20/2024

Emphasis:

Case Closed: 06/20/2024


Related Activity
Type Activity Nr Safety Health
Accident 2176079
Inspection 1756334 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 172556.015
Event: 06/19/2024
Employee is killed when ejected from spider excavator after

At 11:00 a.m. on June 19, 2024, Employee #1, employed by a construction company, was moving a spider excavator to a work location when the excavator fell into a canyon. The operator was ejected from the machine during the fall. Emergency services were called to the scene, but the operator was fatally injured in the incident.

Keywords: Blunt force, Blunt force trauma, Ejected, Excavator, Fall, Seat, Seat Belt, Unconsciousness, Unresponsive

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1757344.015 58 M Fatality Equipment Operator: Heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.