Inspection Detail
Inspection: 17504218 - Chuck'S Hot Oil Service
Inspection Information - Office: Austin Area Office
Site Address:
Chuck'S Hot Oil Service
4 Mi. N. Hwy 696, 7 Mi. E. Of Lexington
Lexington, TX 78947
Mailing Address:
Rt. 4, Box 37a-21, Caldwell, TX 77836
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/31/1986
Emphasis: L:Oilgas
Case Closed: 06/20/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360141675 | ||
Referral | 900662347 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19030002 A01 | 04/23/1986 | 04/26/1986 | $0 | $0 | $0 | - |
Investigation Summary
AT APPROXIMATEKY 5 PM ON MARCH 20, 1986, EMPLOYEE #1 WAS USING A TRUCK MOUNTED HOT OIL UNIT TO PUMP HOT (260 DEGREES) CRUDE OIL, UNDER ABOUT 600 PSI PRESSURE, INTO THE CASING HEAD OF AN OIL AND GAS PRODUCING WELL. THE HOT OIL WAS BEING USED TO MELT PARAFFIN IN THE WELL. AS EMPLOYEE #1 WAS ENGAGED IN THIS OPERATION, ANOTHER EMPLOYEE (EMPLOYEE #2) ARRIVED WITH ANOTHER HOT OIL UNIT AND PARKED ADJACENT TO THE HOT OIL UNIT IN USE. SUDDENLY A DISCHARGE HOSE RUPTURED AND HOT OIL STARTED FLOWING BACK FROM THE WELL. THE HOT OIL WAS IGNITED BY FLAMES FROM THE FIRE BOX OF THE HEATER ON THE UNIT IN USE. EMPLOYEE #1 WAS BURNED OVER 97% OF HIS BODY. EMPLOYEE #2 RECEIVED ONLY MINOR BURNS ON HIS FINGERS WHICH HE SUFFERED WHEN HE WENT TO ASSIST EMPLOYEE #1. BOTH EMPLOYEES WERE TRANSPORTED TO THE HOSPITAL. EMPLOYEE #2 WAS RELEASED THE SAME DAY, BUT EMPLOYEE #1 DIED ON APRIL 17TH AS A RESULT OF THE SEVERE BURNS HE SUFFERED. CAUSAL FACTORS: THE HOT OIL UNIT HAD NO PRESSURE RELIEF DEVICE ON THE PISTON PUMP; THERE WAS NO CHECK VALVE IN THE OIL LINE TO PREVENT BACK FLOW FROM THE WELL; THE DISCHARGE LINE WAS NOT PRESSURE TESTED BEFORE USE.
Keywords: BURN, FIRE, OIL WELL DRILLING, HOSE, RUPTURE, CRUDE OIL, HIGH PRESSURE, HIGH TEMPERATURE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 17504218 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
2 | 17504218 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |