Inspection Detail
Inspection: 17403023 - Liquid Air Engineering Corp.
Inspection Information - Office: Savannah Area Office
Site Address:
Liquid Air Engineering Corp.
East President St. - Liquid Air Corp.
Savannah, GA 31404
Mailing Address:
2121 N. California Blvd., Walnut Creek, CA 94596
Union Status: NonUnion
SIC:8711
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 10/27/1989
Emphasis:
Case Closed: 12/18/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360713598 |
Investigation Summary
Employee #1 was instructed to enter an oxygen-deprived, newly constructed 1,562-cubic-foot air-drier vessel to level out a one-half-inch-diameter activated aluminum material that was dumped inside. The material was used as a desiccant to remove moisture. Two days prior to entry, the vessel had undergone a pressure test using nitrogen gas. However, they did not completely evacuate the gas. Approximately ten minutes after entry, voice contact was lost between the employee inside and others outside. Employee #2 then entered the vessel and died from asphyxia. Employee #3 also passed out after entering the vessel, but he was able to survive after a supervisor placed an air hose inside the vessel. Employee #3 along with the help of Employee #4, who wore a self-contained breathing apparatus, removed the first two from the vessel.
Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, SCBA, TANK, CONFINED SPACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 17403023 | Occupation Not Listed |