Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1711105.015 - Ideal Demolition Services, Llc

Inspection Information - Office: Boise Area Office

 

Inspection Nr: 1711105.015
Report ID: 1032500
Date Opened: 11/17/2023

Site Address:
Ideal Demolition Services, Llc
222 S. Auto Dr.
Boise, ID 83702

Mailing Address:
2473 West Success Way, Emmett, ID 83617

Union Status: NonUnion

SIC:

NAICS: 238910/Site Preparation Contractors


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/17/2023

Emphasis: N:Fall

Case Closed: 04/23/2025


Related Activity
Type Activity Nr Safety Health
Accident 2103765
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $36,870 $0 $0 $0 $0 $36,870
Current Penalty $32,629 $0 $0 $0 $0 $32,629
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260501 B04 I 04/22/2024 05/16/2024 $6,452 $6,452 $0 I - Informal Settlement  
2. 01002 Serious 19260501 B04 I 04/22/2024 05/16/2024 $6,452 $6,452 $0 I - Informal Settlement  
3. 01003 Serious 19260502 D15 II 04/22/2024 05/16/2024 $4,516 $6,452 $0 I - Informal Settlement  
4. 01004 Serious 19260502 D16 III 04/22/2024 05/16/2024 $6,452 $6,452 $0 I - Informal Settlement  
5. 01005 Serious 19260503 A02 04/22/2024 05/16/2024 $6,452 $6,452 $0 I - Informal Settlement  
6. 01006 Serious 19260850 A 04/22/2024 05/16/2024 $2,305 $4,610 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 161859.015
Event: 11/16/2023
Employee falls through skylight and is killed

At 3:00 p.m. on November 16, 2023, Employee #1 was working for a site preparation contractor. Employee #1 was on the roof of building with a co-worker to remove a skylight. Employee #1 picked up one end of skylight and fell through opening to the concrete floor below. Employee #1 was apparently wearing a PFAS, but it appears it was not properly anchored or used. Employee #1 suffered a head injury, fractured ribs and fractured right leg leading to his fatality.

Keywords: Blunt force trauma, Concrete, Concrete Floor, Fall, Fall From Elevation, Fall Protection, Fracture, Head, Leg, Rib, Roof, Roof Opening, Skylight

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1711105.015 19 M Fatality
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.