Inspection Detail
Inspection: 1700715 - Professional Prototypes
Inspection Information - Office: Tampa Area Office
Site Address:
Professional Prototypes
2133 Range Rd
Clearwater, FL 33575
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7532
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/10/1984
Emphasis:
Case Closed: 09/04/1984
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360575039 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $360 | $0 | $0 | $0 | $0 | $360 |
Current Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100304 F05 V | 08/13/1984 | 08/16/1984 | $180 | $360 | $0 | I - Informal Settlement |
Investigation Summary
AN EMPLOYEE WAS USING A SMALL PORTABLE ELECTRIC GRINDER, THE FRAME OF WHICH WAS ENERGIZED AT 50 TO 60 VOLTS, AC, BECAUSE OF LEAKAGE. THE ELECTRIC TOOL WAS NOT GROUNDED. THE EMPLOYEE HAD APPARENTLY JUST DRAINED AN AIR RECEIVER AND HAD WET HANDS WHEN HE STARTED UP THE GRINDER. HE WAS ELECTROCUTED.
Keywords: E GI III, ELECTRICAL, ELECTROCUTED, CURRENT LEAKAGE, GROUND FAULT, EQUIPMENT GROUNDING, ELEC PORT TOOL--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1700715 | Fatality | Electric Shock | Occupation not reported |