Inspection Detail
Inspection: 1697751.015 - Amgen Manufacturing Limited
Inspection Information - Office: Pr-E-Caguas 0257220
Site Address:
Amgen Manufacturing Limited
Carr 31 Km 24.6
Juncos, PR 00777
Mailing Address:
Po Box 4060, Juncos, PR 00777
Union Status: NonUnion
SIC:
NAICS: 325414/Biological Product (except Diagnostic) Manufacturing
Inspection Type: Fat/Cat
Scope: Records
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/12/2023
Emphasis:
Case Closed: 02/29/2024
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 2081661 |
Investigation Summary
At 12:55 p.m. on September 9, 2023, Employee # 1 was practicing an emergency drill. After finishing, he felt dizzy, had heartburn and other symptoms of cardiac problems. His cardiac rhythm increased drastically and suddenly. His blood pressure increases to very high levels. He was killed.
Keywords: Cardiac Arrest, Dizziness, Heart, High Blood Pressure
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1697751.015 | 53 | M | Fatality | Hand packers and packagers |