Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1696185.015 - Tso Inc

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 1696185.015
Report ID: 0522500
Date Opened: 09/07/2023

Site Address:
Tso Inc
11250 Township Road 67
Killbuck, OH 44637

Mailing Address:
15640 Long Run Rd, Saint Louisville, OH 43071

Union Status: NonUnion

SIC:

NAICS: 237130/Power and Communication Line and Related Structures Construction


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/07/2023

Emphasis: N:Fall

Case Closed: 11/14/2025


Related Activity
Type Activity Nr Safety Health
Accident 2078062
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 3 3
Initial Penalty $43,752 $0 $0 $0 $0 $43,752
Current Penalty $22,970 $0 $0 $0 $0 $22,970
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 D02 12/19/2023 01/26/2024 $7,657 $10,938 $0 I - Informal Settlement  
2. 01002 Serious 19100268 B07 12/19/2023 01/26/2024 $7,657 $10,938 $0 I - Informal Settlement  
3. 01003A Serious 19100268 E 12/19/2023 01/26/2024 $7,657 $10,938 $0 I - Informal Settlement  
4. 01003B Serious 19100268 F01 12/19/2023 01/26/2024 $0 $10,938 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 159708.015
Event: 09/06/2023
Employee is electrocuted after contacting overhead powerline

At 3:00 p.m. on September 6, 2023, an employee was preparing to install a fiber optic communication cable onto an elevated support strand from the ground, along an existing power line easement location. After attaching a metal cable roller to the end of the nylon string, which contained a woven tracer wire, the employee threw the roller up towards the cable strand. The roller struck the energized 7,200-volt power line located above. The employee was electrocuted while holding the conductive rope. The employee was killed.

Keywords: Conductive Hose, Contact, Electrocuted, Installing, Optical Fiber Cable, Overhead Power Line, Roller--Const Equip

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1696185.015 46 M Fatality Telecomm: Line Installers And Repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close