Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1690989.015 - Sts Industrial Incorporated

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 1690989.015
Report ID: 0626700
Date Opened: 08/15/2023

Site Address:
Sts Industrial Incorporated
2917e East Roundbunch Road
Orange, TX 77630

Mailing Address:
3067 Carbide Dr., Sulphur, LA 70665

Union Status: NonUnion

SIC:

NAICS: 423710/Hardware Merchant Wholesalers


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/24/2024

Emphasis: N:Amputate

Case Closed: 04/09/2024


Related Activity
Type Activity Nr Safety Health
Accident 2067936
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 10 10
Current Violations 7 7
Initial Penalty $101,631 $0 $0 $0 $0 $101,631
Current Penalty $45,733 $0 $0 $0 $0 $45,733
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100028 B11 II 02/09/2024 $3,871 $6,453 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C01 02/09/2024 $6,775 $11,292 $0 I - Informal Settlement  
3. 01003 Serious 19100147 C04 I 02/09/2024 $0 $11,292 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19100212 A01 02/09/2024 $4,840 $8,067 $0 I - Informal Settlement  
5. 01005A Serious 19100303 F02 02/09/2024 $4,840 $8,067 $0 I - Informal Settlement  
6. 01005B Serious 19100305 B01 II 02/09/2024 $0 $11,292 $0 I - Informal Settlement  
7. 01005C Serious 19100305 B02 I 02/09/2024 $0 $11,292 $0 I - Informal Settlement  
8. 01006 Serious 19100303 G02 I 02/09/2024 02/15/2024 $8,469 $11,292 $0 I - Informal Settlement  
9. 01007 Serious 19100304 G05 02/09/2024 02/15/2024 $8,469 $11,292 $0 I - Informal Settlement  
10. 01010 Serious 19100333 A01 02/09/2024 02/15/2024 $8,469 $11,292 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 159041.015
Event: 08/14/2023
Employee is electrocuted while troubleshooting outlet

At 11:04 a.m. on August 14, 2023, an employee was troubleshooting issues with a MSI NM1 Nut Assembly Table that would not operate. The employee went to the Warehouse Manager and informed him that the wall outlet used to provide power to the table was bad. The manager provided an extension cord for the employee to use to continue troubleshooting the nut assembly table. The employee began investigating the bad outlet, which was behind the table and a metal storage rack. While leaning over to reach the wall outlet, the employee grabbed the metal storage rack and simultaneously made contact with the body of the table. The electrical outlet the employee was investigating was not deenergized and the nut assembly table was switched on and plugged into an extension cord that did not have a ground prong. The employee was electrocuted and died.

Keywords: Assembling, Contact, Electric Cord, Electrocuted, Energized, Outlet, Table, Troubleshooting

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1690989.015 53 M Fatality Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close