Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1684960.015 - Gulf Coast Welding Contractors Llc

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 1684960.015
Report ID: 0626600
Date Opened: 07/19/2023

Site Address:
Gulf Coast Welding Contractors Llc
11011 Sheldon Rd. Induction Line
Houston, TX 77044

Mailing Address:
1109 8th Street, Morgan City, LA 70380

Union Status: NonUnion

SIC:

NAICS: 561311 


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/21/2023

Emphasis:

Case Closed: 12/27/2023


Related Activity
Type Activity Nr Safety Health
Accident 2056396
Inspection 1684942 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 5 1 6
Initial Penalty $25,895 $0 $0 $0 $0 $25,895
Current Penalty $25,895 $0 $0 $0 $0 $25,895
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A05 11/16/2023 $4,465 $4,465 $0 Z - Issued  
2. 01002 Serious 19100304 G05 11/16/2023 $4,465 $4,465 $0 Z - Issued  
3. 01003A Serious 19100305 G01 IV C 11/16/2023 $4,465 $4,465 $0 Z - Issued  
4. 01003B Serious 19100305 G02 III 11/16/2023 $0 $0 $0 Z - Issued  
5. 01004 Serious 19100333 C06 11/16/2023 11/22/2023 $6,250 $6,250 $0 Z - Issued  
6. 01005 Serious 19100335 A01 I 11/16/2023 11/22/2023 $6,250 $6,250 $0 Z - Issued  
7. 02001 Other 19100137 C02 VIII 11/16/2023 11/22/2023 $0 $0 $0 Z - Issued  

Investigation Summary

Investigation Nr: 161261.015
Event: 07/19/2023
Employee is electrocuted when tubing strikes induction coil

At 7:30 am on July 19, 2023, an employee was working on a steel tubing induction line and he was receiving tubing on the conveyor. The employee was waiting for tubing to be fed by the kicker which kicked the tubing in place but it was misaligned. The employee was trying to align the tubing when the backup caused tubing to be lifted up against the induction coils. The contact with the coils caused current to be transmitted through the tubing and the employee was electrocuted.

Keywords: Contact, Conveyor, Electrocuted, Energized, Jammed, Steel Tube

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1684960.015 42 M Fatality Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.