Inspection Detail
Inspection: 1674538.015 - Gcb Industries, Llc
Inspection Information - Office: Austin
Site Address:
Gcb Industries, Llc
8127 Oak Grove Rd
Franklin, TX 77856
Mailing Address:
14149 Interdrive West, Houston, TX 77032
Union Status: NonUnion
SIC:
NAICS: 332410/Power Boiler and Heat Exchanger Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 06/02/2023
Emphasis:
Case Closed: 11/30/2023
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 2036771 | ||
Inspection | 1674539 | Yes | |
Inspection | 1674540 | Yes |
Investigation Summary
At 8:00 a.m. on May 31, 2023, an employee working for a boiler manufacturer was monitoring the commissioning of an auxiliary boiler when the boiler exploded. The employee sustained blunt force trauma from projectile debris and the shock blast wave and was killed.
Keywords: Blunt force, Blunt force trauma, Boiler, Contusion, Explosion, Head, High Pressure, Inspecting, Lack of Work Procedures, Pressure Release, Pressure Vessel, Projectile, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1674538.015 | 50 | M | Fatality |