Case Status: CLOSED

Inspection: 1671027.015 - Culberson Construction, Llc

Inspection Information - Office: El Paso Area Office

 

Inspection Nr: 1671027.015
Report ID: 0627500
Date Opened: 05/17/2023

Site Address:
Culberson Construction, Llc
Hudson 0-66x67 Pad A Lat: 31.767561 Long: -104.012951
Orla, TX 79770

Mailing Address:
4500 Colony Rd., Tolar, TX 76476

Union Status: NonUnion

SIC:

NAICS: 237120/Oil and Gas Pipeline and Related Structures Construction


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/17/2023

Emphasis: L:Oilgas

Case Closed: 01/22/2024


Related Activity
Type Activity Nr Safety Health
Accident 2032094
Inspection 1671064 Yes
Inspection 1671733 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 1 1
Initial Penalty $66,298 $0 $0 $0 $0 $66,298
Current Penalty $0 $0 $0 $7,000 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 10/30/2023 11/17/2023 $0 $14,063 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19260021 B02 10/30/2023 11/17/2023 $0 $10,046 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Other 19260416 A03 10/30/2023 01/22/2024 $7,000 $14,063 $0 I - Informal Settlement  
4. 01004 Serious 19260600 A06 I 10/30/2023 11/17/2023 $0 $14,063 $0 I - Informal Settlement Citation has been deleted.
5. 01005 Serious 19260600 A06 IV 10/30/2023 11/17/2023 $0 $14,063 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 159456.015
Event: 05/16/2023
Employee dies when electrocuted by PIT arc flash

At 3:00 p.m. on May 16, 2023, an employee working as a supervisor for an oil and gas drilling company was operating a powered industrial truck (PIT). The employee was using the PIT boom to reposition a pipe which had been removed from a tank battery. The employee raised the boom and made contact with live power lines. The employee exited the energized PIT and tried to extinguish the flames under the vehicle. The employee died when he was electrocuted by a resulting arc flash.

Keywords: Clearance, Electric Arc Flash, Electric Shock, Electrocuted, Equipment Operator, Fire, Gas Well Drilling, Industrial Truck, Material Handling, Misjudgment, Misjudgment of Hazardous Situation, Multi-employer Worksite, Multiemployer, Oil Well Drilling, PIV, Pipe, Power Lines, Powered Industrial Vehicle, Shock

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1671027.015 28 M Fatality Supervisors, production occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.