Inspection Detail
Inspection: 1664816.015 - Jorge Arturo Elias Martinez
Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114
Site Address:
Jorge Arturo Elias Martinez
806 Banker Drive Sw
Leesburg, VA 20175
Mailing Address:
122 Patrick St Apt 275, Vienna, VA 22180
Union Status: NonUnion
SIC:
NAICS: 238170/Siding Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/04/2023
Emphasis: S:Ohpwrlne, S:Scaffold
Case Closed: 09/27/2023
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 2085980 | ||
Inspection | 1661078 | Yes | |
Inspection | 1661079 | Yes |
Investigation Summary
At 1:00 p.m. on April 4, 2023, an employee was disassembling a pump jack scaffold. The legs of the pump jack scaffold made contact with the overhead power lines. The employee sustained fatal electrocution injuries, an amputation, and electric burns.
Keywords: Amputated, Amputation, Disassemble, Electrical Burn, Electrocuted, Overhead Power Line, Pump Jack Scaffold
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1664816.015 | 45 | M | Hospitalized injury | ||
2 | 1664816.015 | 42 | M | Fatality |