Inspection Detail
Inspection: 1661008 - Frank Stewart Siding Contractor
Inspection Information - Office: Columbus Area Office
Site Address:
Frank Stewart Siding Contractor
630 Cemetery Rd
Martins Ferry, OH 43935
Mailing Address:
50721 Rehm Road St, Clairsville, OH 43950
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/09/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/20/1984
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360541205 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 6 | 7 | |||
Current Violations | 1 | 6 | 7 | |||
Initial Penalty | $350 | $0 | $0 | $0 | $0 | $350 |
Current Penalty | $50 | $0 | $0 | $0 | $0 | $50 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260450 A11 | 05/22/1984 | 05/25/1984 | $50 | $350 | $0 | I - Informal Settlement | ||
2. | 02001 | Other | 19030002 A01 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - | ||
3. | 02002 | Other | 19040008 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - | ||
4. | 02003 | Other | 19260451 A04 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - | ||
5. | 02004 | Other | 19260451 S01 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - | ||
6. | 02005 | Other | 19260451 S03 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - | ||
7. | 02006 | Other | 19260451 S05 | 05/22/1984 | 05/25/1984 | $0 | $0 | $0 | - |
Investigation Summary
ONE EMPLOYEE WAS HANDING ANOTHER A SPOUTING GUTTER. THE SECOND EMPLOYEE WAS ON A LADDER JACK SCAFFOLD 22 FEET FROM THE GROUND, AND THE FIRST WAS ON THE LADDER BELOW THE SCAFFOLD. THE GUTTER CONTACTED A 7200-VOLT OVERHEAD POWER LINE. THE ELECTRIC SHOCK KNOCKED THE SECOND EMPLOYEE OFF THE LADDER, AND HE FELL TO THE GROUND AND LATER DIED. THE FIRST EMPLOYEE WAS KNOCKED OUT AND FELL ACROSS THE SCAFFOLD. HE WAS HOSPITALIZED.
Keywords: RAIN SPOUT, OVERHEAD POWER LINE, ELECTRICAL, LADDER, CONSTRUCTION, E C, LADDER JACK SCAFFOLD, ELECTRIC SHOCK, FALL, SCAFFOLD
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1661008 | Hospitalized injury | Electric Shock | Construction trades, n.e.c. | ||
2 | 1661008 | Fatality | Electric Shock | Construction trades, n.e.c. |