Powered by GoogleTranslate

Inspection Detail

Inspection: 1656271 - Courtad Construction Systems Inc

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1656271
Report ID: 0418800
Date Opened: 03/28/1984

Site Address:
Courtad Construction Systems Inc
188 W Camino Real
Boca Raton, FL 33432

Mailing Address:
2128 E Auroro Rd, Twinsburg, OH 44087

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/28/1984

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/15/1984


Related Activity
Type Activity Nr Safety Health
Accident 360071807
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $420 $0 $0 $0 $0 $420
Current Penalty $420 $0 $0 $0 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260400 H01 04/13/1984 04/16/1984 $420 $420 $0 -  
2. 01002 Other 19260402 A10 04/13/1984 04/16/1984 $0 $0 $0 -  
3. 02001 Other 19260100 A 04/13/1984 04/18/1984 $0 $0 $0 -  
4. 02002 Other 19260400 A 011012 04/13/1984 04/16/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14525364
Event: 03/27/1984
ELECTRIC SHOCK - UTILIZATION EQUIPMENT

AN EMPLOYEE WAS ENGAGED IN OPERATIONS RELATED TO SECURING SHEET ALUMINUM TO A MANSARD ROOF OVERHANG OF A NEW BUILDING. HE CLIMBED A WOODEN EXTENSION LADDER TO THE ROOF FRAMING, APPROXIMATELY 16 FEET ABOVE GROUND LEVEL. HE WAS CARRYING AN ELECTRIC SCREW GUN IN ONE HAND AND HAD CORD SETS SLUNG OVER HIS SHOULDER. HE TURNED SLIGHTLY AND SAID THAT HE HAD BEEN SHOCKED. THEN HE FELL TO THE GROUND, STRIKING A PROTRUDING SCAFFOLD PLANK ON THE WAY DOWN. HE IMMEDIATELY GOT UP, SAYING AGAIN THAT HE HAD BEEN SHOCKED, TOOK ABOUT 2 STEPS, AND FELL DOWN AGAIN. HE DIED OF ELECTROCUTION. A PERMANENT RECEPTACLE OUTLET INSTALLED IN AN EXISTING BUILDING, ABOUT 300 FEET AWAY, WAS BEING USED TO PROVIDE POWER TO THE SCREW GUN THROUGH THE CORD SETS. NONE OF THE RECEPTACLES WERE GFCI-PROTECTED, NOR WAS THERE AN ASSURED EQUIPMENT GROUNDING CONDUCTOR PROGRAM IN EFFECT. A CHECK OF THE TOOL AND CORDS ALLEGED TO HAVE BEEN USED GAVE NO INDICATION OF WHAT CAUSED THE ELECTRIC SHOCK.

Keywords: ELECTRIC SCREW GUN, ELECTRICAL, CORD SET, ELECTROCUTED, E C, TEMPORARY WIRING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1656271 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.