Inspection Detail
Inspection: 1630730 - Dr William K Bays Dba Burnt Tree Mobile Home Park
Inspection Information - Office: Atlanta East Area Office
Site Address:
Dr William K Bays Dba Burnt Tree Mobile Home Park
Westover Road At Oakridge Dr
Albany, GA 31702
Mailing Address:
1105 4th Ave, Albany, GA 31702
Union Status: NonUnion
SIC:6515
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/04/1984
Emphasis:
Case Closed: 03/16/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360564991 | ||
| Referral | 900533134 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $120 | $0 | $0 | $0 | $0 | $120 |
| Current Penalty | $120 | $0 | $0 | $0 | $0 | $120 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260652 B | 05/23/1984 | 05/26/1984 | $120 | $120 | $0 | - | ||
| 2. | 01001B | Serious | 19260652 H | 05/23/1984 | 05/26/1984 | $0 | $0 | $0 | - |
Investigation Summary
TWO EMPLOYEES OF A MOBILE HOME PARK MAINTENANCE CREW WERE INSTALLING A 6 INCH PVC SEWER LINE TO A NEWLY CLEARED LOT. THE TRENCH WAS APPROXIMATLEY FIFTY FEET LONG, THIRTY INCHES WIDE AND SEVEN FEET DEEP. EMPLOYEE #1 WAS IN THE TRENCH, TAMPING DIRT AROUND THE PIPE THIRTY FEET FROM THE CONNECTION POINT AND TWENTY FEET FROM THE END POINT. EMPLOYEE #2 WAS ON TOP OF THE EDGE OF THE TRENCH ON THE SPOIL BANK SIDE. HE WAS SHOVELING DIRT INTO THE TRENCH. WITHOUT WARNING THE OPPOSITE WALL BROKE OUT (ABOUT A 10-15 FOOT SECTION) ABOUT ONE FOOT BELOW THE TOP EDGE. THE CAVE-IN CAUGHT EMPLOYEE #1 AND COVERED HIM TO A POINT JUST OVER HIS HEAD. EMPLOYEE #2 UNCOVERED HIS HEAD AND WENT FOR HELP. EMERGENCY MEDICAL PEOPLE WERE ABLE TO REVIVE EMPLOYEE #1 AT THE HOSPITAL.
Keywords: SEWER, TRENCH, BURIED, CAVE-IN
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1630730 | Hospitalized injury | Asphyxia | Occupation not reported |