Inspection Detail
Note: The following inspection has not been indicated as closed. OSHA citation items will be posted 30 (thirty) days after the employer receives the citation(s), except in cases of significant public interest. Posted citation items reflect any amendments to citations that are the result of a prompt settlement, which OSHA encourages. Employers and employee representatives will continue to receive copies of the citation(s) upon issuance.
Inspection: 1604540.015 - Sunrun Installation Services, Inc.
Inspection Information - Office: Bakersfield District Office
Site Address:
Sunrun Installation Services, Inc.
209 Duncan Creek Court
Bakersfield, CA 93305
Mailing Address:
2501 Union Avenue, Bakersfield, CA 93305
Union Status: NonUnion
SIC:
NAICS: 238210/Electrical Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/21/2022
Emphasis:
Case Closed:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1911281 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $40,500 | $0 | $0 | $185 | $0 | $40,685 |
Current Penalty | $40,500 | $0 | $0 | $185 | $0 | $40,685 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203(A) | 12/21/2022 | 01/09/2023 | $185 | $185 | $0 | 03/02/2023 | C - Contested | |
2. | 02001 | Serious | 23200003 | 12/21/2022 | 01/03/2023 | $22,500 | $22,500 | $0 | 03/02/2023 | C - Contested | |
3. | 03001 | Serious | 23200004 A | 12/21/2022 | 01/03/2023 | $18,000 | $18,000 | $0 | 03/02/2023 | C - Contested |
Investigation Summary
At 5:00 p.m. on June 23, 2022, an employee was working on a roof-mounted solar panel system when he made contact with an energized electrical component. The employee collapsed on the roof and was pronounced dead due to electrocution.
Keywords: Contact, Electrocuted, Energized, Functional Component, Installing, Roof, Solar, Solar Array
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1604540.015 | 27 | M | Fatality | Installers And Repairers |