Inspection Detail
Inspection: 1596902.015 - Northrop Grumman Corporation
Inspection Information - Office: Va-E-Manassas (Regional Office) - Health 0355125
Site Address:
Northrop Grumman Corporation
21834 Atlantic Boulevard Building 5
Sterling, VA 20166
Mailing Address:
2980 Fairview Park Drive, Falls Church, VA 22042
Union Status: NonUnion
SIC:
NAICS: 334511/ Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/19/2022
Emphasis: S:Fri
Case Closed: 11/09/2022
Investigation Summary
At 8:38 a.m. on May 19, 2022, an employee purged the Nitrogen lines of the battery freezers in a lab room and the freezers filled up with Nitrogen gas. The victim closed himself into one of the freezers, where he eventually died from the overexposure to Nitrogen gas and lack of oxygen.
Keywords: Freezer Compartment, Lack of oxygen, Nitrogen, Overexposure
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1596902.015 | 47 | M | Fatality | Electrical and electronic engineers |