Inspection Detail
Inspection: 1595228.015 - Ingram Barge Company, Llc
Inspection Information - Office: Nashville Area Office
Site Address:
Ingram Barge Company, Llc
4116 Clarks River Road
Paducah, KY 42001
Mailing Address:
4400 Harding Pike, Nashville, TN 37205
Union Status: NonUnion
SIC:
NAICS: 336611/Ship Building and Repairing
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/2022
Emphasis: L:Maritime
Case Closed: 04/13/2023
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1893559 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $39,364 | $0 | $0 | $0 | $0 | $39,364 |
Current Penalty | $16,215 | $0 | $0 | $6,215 | $0 | $22,430 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19100305 B01 I | 11/08/2022 | $6,215 | $12,431 | $0 | 12/02/2022 | F - Formal Settlement | ||
2. | 01002 | Serious | 19100305 G02 III | 11/08/2022 | $6,215 | $12,431 | $0 | 12/02/2022 | F - Formal Settlement | ||
3. | 01003 | Serious | 19150056 C05 | 11/08/2022 | 11/21/2022 | $10,000 | $14,502 | $0 | 12/02/2022 | F - Formal Settlement |
Investigation Summary
At 3:30 p.m. on May 10, 2022, an employee was disconnecting an air hose coupler from the plasma cutter. The employee was electrocuted by a plasma utter generated direct current and killed.
Keywords: Air Hose, Cutting, Direct Current, Electrocuted
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1595228.015 | 22 | M | Fatality | Welders and cutters |