Inspection Detail
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection: 1593602.015 - Bmz Roofing
Inspection Information - Office: Wyoming
Site Address:
Bmz Roofing
3345 Cody Ln
Teton Village, WY 83025
Mailing Address:
1095 Western Drive Lot 391 G, Colorado Springs, CO 80909
Union Status: NonUnion
SIC:
NAICS: 236116/New Multifamily Housing Construction (except Operative Builders)
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/02/2022
Emphasis: S:Constr
Case Closed:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1889223 | ||
Inspection | 1594758 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $7,956 | $0 | $0 | $5,000 | $0 | $12,956 |
Current Penalty | $7,956 | $0 | $0 | $5,000 | $0 | $12,956 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260501 B11 | 08/10/2022 | 09/06/2022 | $3,978 | $3,978 | $0 | Z - Issued | ||
2. | 01002 | Serious | 19260503 A01 | 08/10/2022 | 09/06/2022 | $3,978 | $3,978 | $0 | Z - Issued | ||
3. | 02001 | Other | 19040039 A01 | 08/10/2022 | 09/06/2022 | $5,000 | $5,000 | $0 | Z - Issued |
Investigation Summary
At 8:25 a.m. on April 27, 2022, an employee was tearing cedar shake shingles off a 5/12 pitch roof 60 feet off the ground without using the provided fall protection. The employee stepped onto a plastic covering on the west side of the roof when he fell. The employee impacted the concrete pavement below head first and was killed. The narrative indicated that the employee was possibly preparing to tie off before he started work. The narrative does not explain why he did not complete tie-off but does indicate PPE may have been insufficient.
Keywords:anchor, blunt force, blunt force trauma, brain, building, concrete, fall, fall from elevation, fall protection, harness, head, lanyard, misjudgement, misjudgement of hazardous situation, ppe, ppe hazard assessment, p
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1593602.015 | Fatality | Roofers |