Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1580927.015 - Illinois Engineered Products, Inc.

Inspection Information - Office: Chicago South Area Office

 

Inspection Nr: 1580927.015
Report ID: 0521700
Date Opened: 03/01/2022

Site Address:
Illinois Engineered Products, Inc.
2415 W. 21st Street
Chicago, IL 60608

Mailing Address:
2415 W. 21st Street, Chicago, IL 60608

Union Status: NonUnion

SIC:

NAICS: 333517 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/17/2022

Emphasis: N:Amputate

Case Closed: 06/29/2023


Related Activity
Type Activity Nr Safety Health
Referral 1868669 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $11,602 $0 $0 $0 $0 $11,602
Current Penalty $8,000 $0 $0 $0 $0 $8,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 05/19/2022 06/08/2022 $4,000 $5,801 $0 I - Informal Settlement  
2. 01002 Serious 19100212 A01 05/19/2022 06/08/2022 $4,000 $5,801 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 144159.015
Event: 02/21/2022
Employee amputates fingers while using unguarded machinery

At 10:15 a.m. on February 21, 2022, Employee #1 was operating a hydro-mechanical brake press machine. Employee #1, a machine operator, was bending parts on a mechanical brake press machine. Employee #1 had been placing parts into the machine and using a foot pedal to actuate the machine in order to bend the parts. Employee #1 placed the part into the machine and pressed the foot pedal. At this moment, Employee #1's middle and ring fingers on the left hand were severed. Employee #1 was taken to a local hospital and hospitalized for a day. Employee #1's middle finger was reattached and the ring finger was a complete fingertip amputation.

Keywords: Amputated, Amputation, Finger, Fingertip, Machine Guarding, Machine operator, Press Brake, Press Operator, Unguarded

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1580927.015 43 F Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close