Inspection Detail
Inspection: 1580494.015 - Production Framing, Inc.
Inspection Information - Office: Oakland District Office
Site Address:
Production Framing, Inc.
28951 Ashwell Avenue
Hayward, CA 94544
Mailing Address:
2000 Opportunity Drive Ste. 140, Roseville, CA 95678
Union Status: NonUnion
SIC:
NAICS: 238130/Framing Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/26/2022
Emphasis:
Case Closed: 05/27/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1867930 | ||
| Inspection | 1580504 | Yes |
Investigation Summary
On or about 1: 42 p.m. on February 15, 2022, Employee #1 was standing on a Guardian stacker bracket scaffold system/assembly which had guard rails installed. As Employee #1 started removing the planking of the adjacent bracketed scaffold, the top clamp bolt securing the bracket to the wall of the building failed/loosened. As a result, Employee #1 fell to the ground 28 feet and suffered fracture of the right clavicle. The employee was hospitalized for treatment.
Keywords: Bolt, Building, Clamp, Clavicle, Guardrail, Planking, Scaffold
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1580494.015 | 42 | M | Hospitalized injury | Carpenter |
Translate