Inspection Detail
Inspection: 1580018 - Tad Technical Services Corp
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Tad Technical Services Corp
7400 Nw 50th St
Bethany, OK 73123
Mailing Address:
13612 Midway Rd, Dallas, TX 75234
Union Status: NonUnion
SIC:7363
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/11/1984
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/19/1984
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360566616 |
Investigation Summary
Employee #1, a contract employee, was assisting in the pouring of molten quartzite into a sand mold. After approximately 25 minutes, when the pouring operation was approximately 75 percent complete, the mold blew up, spewing molten metal to the ceiling, onto the floor, and over Employee #1. He was not wearing any protective gear other than safety glasses, and sustained burns that required hospitalization. (For associated report on other employees involved in this accident, see ID #014494546.)
Keywords: BURN, PPE, WORK RULES, EXPLOSION, MOLTEN METAL, MOLD
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1580018 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |