Inspection Detail
Inspection: 1578586.015 - Pall Aeropower Corporation
Inspection Information - Office: Tampa Area Office
Site Address:
Pall Aeropower Corporation
10540 Ridge Road
New Port Richey, FL 34654
Mailing Address:
10540 Ridge Road, New Port Richey, FL 34654
Union Status: NonUnion
SIC:
NAICS: 333999/All Other Miscellaneous General Purpose Machinery Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/16/2022
Emphasis:
Case Closed: 05/16/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1860454 | Yes |
Investigation Summary
At 12:00 noon on January 28, 2022, an employee was operating a Hydrogen Induction Bracing machine when an explosion occurred. The employee was hospitalized for treatment of burns.
Keywords: Bracing, Burn, Explosion, Fire, Hydrogen
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1578586.015 | 60 | F | Hospitalized injury | Machine operators, not specified |