Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1571213.015 - B&B Roustabout, Inc

Inspection Information - Office: Lubbock Area Office

 

Inspection Nr: 1571213.015
Report ID: 0627510
Date Opened: 01/05/2022

Site Address:
B&B Roustabout, Inc
Big Spring E. Battery
Big Spring, TX 79720

Mailing Address:
P.O. Box 421, Lamesa, TX 79331

Union Status: NonUnion

SIC:

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/05/2022

Emphasis: P:Oilgas, L:Oilgas, L:Tankclean6

Case Closed: 05/24/2022


Related Activity
Type Activity Nr Safety Health
Referral 1847639 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $14,088 $0 $0 $0 $0 $14,088
Current Penalty $8,453 $0 $0 $0 $0 $8,453
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 B06 04/18/2022 05/16/2022 $3,481 $5,801 $0 I - Informal Settlement  
2. 01002 Serious 19100132 D01 04/18/2022 05/16/2022 $1,492 $2,486 $0 I - Informal Settlement  
3. 01003A Serious 19100151 B 04/18/2022 05/16/2022 $1,492 $2,486 $0 I - Informal Settlement  
4. 01003B Serious 19100151 C 04/18/2022 05/16/2022 $0 $0 $0 I - Informal Settlement  
5. 01004A Serious 19101200 E01 04/18/2022 05/16/2022 $1,989 $3,315 $0 I - Informal Settlement  
6. 01004B Serious 19101200 G08 04/18/2022 05/16/2022 $0 $0 $0 I - Informal Settlement  
7. 01004C Serious 19101200 H01 04/18/2022 05/16/2022 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 145225.015
Event: 12/24/2021
Employees cleaning fuel tanks are injured in explosion

At 10:00 a.m. on December 24, 2021, three employees were working for a firm that provided support activities for oil and gas operations. They were cleaning fuel tanks. They had to unbolt hatches to gain access to the tanks. To loosen the hatches, they were using a ratchet wrench, a hand drill with an extension cord, and WD-40. The employees were using a DeWalt electricelectric impact wrench to remove and replace the bolts holding the cover on the tank battery. A Pulsar PG3500MR gasoline-powered generator and a Briggs & Stratton CR950 gasoline-powered compressor mounted to a company truck supplied power to the power tools by way of an extension cord. As the employees unbolted the hatch of the second tank, an explosion occurred. The employees suffered burns. All three employees were hospitalized. The extension cord was charred by the fire and left in the area where the explosion had occurred.

Keywords: Burn, Compressed Air, Compressor, Cord Set, Electric Cord, Electric Generator, Explosion, Flammable Vapors, Fuel Tank, Gas Generator, Hand Tool, Hatch, Portable Power Tool, Vapor

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1571213.015 44 M Hospitalized injury
2 1571213.015 27 M Hospitalized injury
3 1571213.015 37 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close