Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1570346.015 - Colt Services, Lp

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 1570346.015
Report ID: 0626600
Date Opened: 12/23/2021

Site Address:
Colt Services, Lp
3525 Decker Dr.
Baytown, TX 77520

Mailing Address:
626 North 16th Street, La Porte, TX 77571

Union Status: NonUnion

SIC:

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/23/2021

Emphasis:

Case Closed: 08/05/2022


Related Activity
Type Activity Nr Safety Health
Referral 1847188 Yes Yes
Referral 1847150 Yes Yes
Referral 1847166 Yes Yes
Inspection 1570275 Yes
Inspection 1570344 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $9,136 $0 $0 $0 $0 $9,136
Current Penalty $0 $0 $0 $9,136 $0 $9,136
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100119 H03 IV 06/03/2022 06/23/2022 $9,136 $9,136 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 142282.015
Event: 12/23/2021
Employee suffers burns and fracture in explosion at refinery

An employee was working for a contractor that supported gas and oil operations. On or before December 21, 2021, a leak was found on a flange for a bypass line on the Hydro Desulfurization Unit (HDU-1) at refinery operated by an international oil company. The leak was detected because the leak had auto ignited. The refinery owner's fire team had been called out to put the fire out. After the fire was out, steam lances were continuously directed on the flange due to the potential of another flash fire from the leaking heated naphtha. The refinery's owner hired two contract companies to repair the leaking flange using a method called hot bolting. In this method, one bolt at a time was removed and replaced so that workers could install a wire wrap and seal the leak. The replacement bolts were longer and had injection collars. Workers would do the wire wrap and inject the bolts with a sealant to stop the leak. At 1:00 a.m. on December 23, 2021, an employee was working for the contracting firm that would remove and replace the bolts, while the other contractor assisted. As the employee was waiting for the other contractor, an explosion occurred during the repair. The employee suffered second-degree burns. In addition, he suffered a fractured femur when he was struck by a flying object from the explosion. He was hospitalized. Another worker there was not hospitalized. The employee's supervisors knew that the flange had auto ignited the day before they were called to come and fix the leak. The supervisors did not, though, ensure that employees had upgraded their personal protective equipment (PPE) to reduce the risk of serious injuries should a flash fire reoccur. They did not evaluate the hazards and select and require the use of appropriate PPE using their knowledge of the operating conditions, nor did they use refinery owner's safe work practice requirement of using upgraded PPE when work activity is going to be done in areas with potential flash fire.

Keywords: Burn, Explosion, Flange, Flying Object, Fracture, Gas Leak, Hot Work, Leak, Leg, Multi-employer Worksite, Multiemployer, Naphtha, PPE, Process Safety, Refinery, Skin, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1570346.015 30 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close