Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1569778.015 - Franklin Manufacturing, Inc.

Inspection Information - Office: Birmingham Area Office

 

Inspection Nr: 1569778.015
Report ID: 0418300
Date Opened: 12/20/2021

Site Address:
Franklin Manufacturing, Inc.
15825 Hwy 243 Industrial Park
Russellville, AL 35653

Mailing Address:
P.O. Box 998 Attn: Darrell Johnson, Russellville, AL 35653

Union Status: NonUnion

SIC:

NAICS: 333517 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/08/2022

Emphasis:

Case Closed: 10/12/2022


Related Activity
Type Activity Nr Safety Health
Referral 1843679 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $8,702 $0 $0 $0 $0 $8,702
Current Penalty $0 $0 $0 $6,000 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100132 D01 06/08/2022 08/08/2022 $6,000 $8,702 $0 I - Informal Settlement  
2. 02001 Other 19100132 D02 06/08/2022 07/06/2022 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 142145.015
Event: 12/15/2021
Employee amputates fingertip when pneumatic cylinder returns

At 3:00 p.m. on December 15, 2021, an employee was testing the operation of a pneumatic cylinder and gears in a centering device prior to installing the housing cover. The employee placed his hand on the device assembly to steady it during operation and applied air to the steel cylinder. The cylinder returned with sufficient force to amputate his left pinky fingertip to the distal joint. The employee was treated without hospitalization.

Keywords: Air Pressure, Amputated, Amputation, Assembling, Assembly Line, Engineering Controls, Finger, Fingertip, Gear, High Pressure, Inexperience, Insufficient Supervision, Lack of Engineering Controls, Lack of Work Procedures, Misjudgment, Misjudgment of Hazardous Situation, Partial Amputation, Pneumatic, Pneumatic cylinder, Pneumatic equipment, Supervision, Testing, Training

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1569778.015 30 M Non Hospitalized injury Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close