Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: CLOSED

Inspection: 1568341.015 - Titan Solar Power Nv, Inc.

Inspection Information - Office: Nevada Las Vegas

 

Inspection Nr: 1568341.015
Report ID: 0953220
Date Opened: 12/13/2021

Site Address:
Titan Solar Power Nv, Inc.
694 Glowing Horizon Street
Henderson, NV 89012

Mailing Address:
3570 West Post Road, Las Vegas, NV 89118

Union Status: NonUnion

SIC:

NAICS: 238210/Electrical Contractors


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/31/2022

Emphasis: N:Covid-19

Case Closed: 02/11/2022


Case Status: CLOSED

Investigation Summary

Investigation Nr: 141892.015
Event: 12/13/2021
Employee Falls From Roof And Is Killed

At 1:25 p.m. on December 13, 2021, an employee worked to install a solar array r ack on a residential roof. At some point, the employee fell approximately twenty -six feet and was killed by a head injury.

Keywords:fall, fall from elevation, fall protection, head, installing, roof, solar array

Investigated Inspection
# Inspection Age Sex Degree Nature Occupation
1 1568341.015 Fatality Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close