Inspection Detail
Inspection: 1565879.015 - Entact, Llc
Inspection Information - Office: Fairview Heights Area Office
Site Address:
Entact, Llc
1 Illinois St.
Lawrenceville, IL 62439
Mailing Address:
1 Oak Drive, Westmont, IL 60559
Union Status: NonUnion
SIC:
NAICS: 562910/Remediation Services
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/29/2021
Emphasis:
Case Closed: 02/12/2024
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1835944 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $26,418 | $0 | $0 | $0 | $0 | $26,418 |
Current Penalty | $0 | $0 | $0 | $14,676 | $0 | $14,676 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19100269 L01 I | 04/21/2022 | 05/17/2022 | $5,870 | $8,806 | $0 | 05/20/2022 | F - Formal Settlement | |
2. | 01002 | Serious | 19100269 L03 I | 04/21/2022 | 05/17/2022 | $0 | $8,806 | $0 | 05/20/2022 | F - Formal Settlement | Citation has been deleted. |
3. | 01003 | Other | 19100269 N02 | 04/21/2022 | 05/17/2022 | $8,806 | $8,806 | $0 | 05/20/2022 | F - Formal Settlement |
Investigation Summary
At 7:55 a.m. on November 17, 2021, an employee was repositioning orange plastic fencing markers on the line from an aerial lift basket within one foot of an electric utility line. After engaging an air brake on the line approximately 430 feet away, a coworker verified that the brake was engaged, and a multi-hasp lock and tag were placed on the air brake control. However a voltage detector was not used to verify that the line was de-energized. As the employee threw the fencing on to the line, an arc occurred between the line and the employee. A jumper wire on the utility side of the switch had moved out of position and made direct contact with the switch, bypassing the air gap created by the ground switch. Under the bypass condition, the line had approximately 10 kV of electricity. The employee was hospitalized for treatment of burns to right hand, with hole under middle finger through palm, burns to left hand, exit hole on left forearm.
Keywords: Air Brake, Elec Utility Work, Electric Arc, Electric Shock, Electrical Burn, Energized, Finger, Forearm, Hand
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1565879.015 | 54 | M | Hospitalized injury | Laborers, except construction |