Inspection Detail
Inspection: 1562232.015 - Amb Enterprises, Inc.
Inspection Information - Office: Hasbrouck Heights Area Office
Site Address:
Amb Enterprises, Inc.
25 Lake Street
Paterson, NJ 07501
Mailing Address:
25 Lake Street, Paterson, NJ 07501
Union Status: NonUnion
SIC:
NAICS: 424990/Other Miscellaneous Nondurable Goods Merchant Wholesalers
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/11/2022
Emphasis:
Case Closed: 07/15/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1830752 | Yes | |
Inspection | 1564535 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 6 | 6 | ||||
Initial Penalty | $19,890 | $0 | $0 | $0 | $0 | $19,890 |
Current Penalty | $12,929 | $0 | $0 | $0 | $0 | $12,929 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100110 E04 III | 03/03/2022 | $2,155 | $3,315 | $0 | I - Informal Settlement | |||
2. | 01002 | Serious | 19100178 L01 I | 03/03/2022 | $2,155 | $3,315 | $0 | I - Informal Settlement | |||
3. | 01003 | Serious | 19100178 Q07 | 03/03/2022 | $2,155 | $3,315 | $0 | I - Informal Settlement | |||
4. | 01004 | Serious | 19100303 B07 I | 03/03/2022 | $2,155 | $3,315 | $0 | I - Informal Settlement | |||
5. | 01005 | Serious | 19100303 F02 | 03/03/2022 | $1,616 | $2,486 | $0 | I - Informal Settlement | |||
6. | 01006 | Serious | 19100304 F02 II | 03/03/2022 | $2,694 | $4,144 | $0 | I - Informal Settlement |
Investigation Summary
At 3:15 p.m. on November 3, 2021, an employee was working for a firm that manufactured adhesives. He was setting up equipment to pump a solution of hot water and boric acid in the facility's tote bin 106 into tank 9. The narrative did not state the temperature of the solution. The hose attached to the tote bin was not secured properly. It became detached, and the hot solution spilled out. Some got on the employee. He suffered first- and second-degree burns to his left leg. He received a chemical burn from the boric acid as well. He was treated without hospitalization.
Keywords: Burn, Chemical, Chemical Burn, Chemical Exposure, Hose, Hot Water, Leg, Pump, Solution, Spill, Tank, Unsecured
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1562232.015 | 42 | M | Non Hospitalized injury |