Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1562232.015 - Amb Enterprises, Inc.

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 1562232.015
Report ID: 0214500
Date Opened: 11/04/2021

Site Address:
Amb Enterprises, Inc.
25 Lake Street
Paterson, NJ 07501

Mailing Address:
25 Lake Street, Paterson, NJ 07501

Union Status: NonUnion

SIC:

NAICS: 424990/Other Miscellaneous Nondurable Goods Merchant Wholesalers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/11/2022

Emphasis:

Case Closed: 07/15/2022


Related Activity
Type Activity Nr Safety Health
Referral 1830752 Yes
Inspection 1564535 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $19,890 $0 $0 $0 $0 $19,890
Current Penalty $12,929 $0 $0 $0 $0 $12,929
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100110 E04 III 03/03/2022 $2,155 $3,315 $0 I - Informal Settlement  
2. 01002 Serious 19100178 L01 I 03/03/2022 $2,155 $3,315 $0 I - Informal Settlement  
3. 01003 Serious 19100178 Q07 03/03/2022 $2,155 $3,315 $0 I - Informal Settlement  
4. 01004 Serious 19100303 B07 I 03/03/2022 $2,155 $3,315 $0 I - Informal Settlement  
5. 01005 Serious 19100303 F02 03/03/2022 $1,616 $2,486 $0 I - Informal Settlement  
6. 01006 Serious 19100304 F02 II 03/03/2022 $2,694 $4,144 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 143591.015
Event: 11/03/2021
Employee suffers burns to leg when hose detaches

At 3:15 p.m. on November 3, 2021, an employee was working for a firm that manufactured adhesives. He was setting up equipment to pump a solution of hot water and boric acid in the facility's tote bin 106 into tank 9. The narrative did not state the temperature of the solution. The hose attached to the tote bin was not secured properly. It became detached, and the hot solution spilled out. Some got on the employee. He suffered first- and second-degree burns to his left leg. He received a chemical burn from the boric acid as well. He was treated without hospitalization.

Keywords: Burn, Chemical, Chemical Burn, Chemical Exposure, Hose, Hot Water, Leg, Pump, Solution, Spill, Tank, Unsecured

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1562232.015 42 M Non Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close