Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1562195.015 - Lex Products, Llc

Inspection Information - Office: Bridgeport Area Office

 

Inspection Nr: 1562195.015
Report ID: 0111500
Date Opened: 11/05/2021

Site Address:
Lex Products, Llc
11 Forest Parkway
Shelton, CT 06484

Mailing Address:
11 Forest Parkway, Shelton, CT 06484

Union Status: NonUnion

SIC:

NAICS: 423690/Other Electronic Parts and Equipment Merchant Wholesalers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/06/2022

Emphasis: N:Amputate

Case Closed: 07/27/2022


Related Activity
Type Activity Nr Safety Health
Referral 1829764 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $14,502 $0 $0 $0 $0 $14,502
Current Penalty $10,151 $0 $0 $0 $0 $10,151
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 03/16/2022 $10,151 $14,502 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 140873.015
Event: 11/02/2021
End of worker's finger is amputated when mold table retracts

At 9:30 a.m. on November 2, 2021, an employee was working as a machine operator for a wholesaler of electronic parts and equipment. He was operating a Yuhdak model YHS-100-C-25 plastic injection molding machine (serial number TNI905-038). It ran on a three-phase 208-volt supply and required 125 amps. In operation, part, but not all, of the machine was guarded by light curtains. As the production coordinator of the overmold area noted, the light curtains applied only to the closing of the guard on the mold. The light curtains and mold guard were not interlocked with the machine's retractable table. The light curtains could stop the mold guard, but the mold table was still free to retract to the left. The production manager and supervisor stated that employees had been trained not to place their hands under the mold guard, and that signs saying "Keep hands away" had been posted on the front of the mold guard. At the time of the incident, the employee was making an electronic cable. The mold had opened inside the guard, which stayed shut. The retractable table was to the right. The employee had his right-hand pointer or index finger in a large hole on the table, where the injection of plastic would take place. Using his left hand, he reached up under the mold guard to the top of the mold. This was not normal for him, but he wanted to speed up the removal of the part, or shot. The table moved toward the left, taking about two to three seconds. The employee's right index finger was still in the hole on the table. The finger was amputated to the first joint. The employee was treated without hospitalization. The employee had been trained that to remove a part from the mold, he needed to wait for the table to move to the left. Only then could he remove the part. If there was a jam, the operator was stop the mold, push both buttons, and check to see what happened. The employer had trained the operators not to place their hands under the guard when the mold was up.

Keywords: Amputated, Amputation, Die Guard, Finger, Fingertip, Guard, Interlock, Light Curtain, Machine Cycled, Machine Guarding, Mold, Molding Machine, Training, Unguarded

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1562195.015 46 M Non Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close