Inspection Detail
Inspection: 1561040.015 - Repligen Corporation
Inspection Information - Office: Albany Area Office
Site Address:
Repligen Corporation
1 Fairchild Square
Clifton Park, NY 12065
Mailing Address:
1 Fairchild Square, Clifton Park, NY 12065
Union Status: NonUnion
SIC:
NAICS: 339112/Surgical and Medical Instrument Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/28/2021
Emphasis:
Case Closed: 04/22/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1827083 | Yes |
Investigation Summary
At 7:30 a.m. on October 26, 2021, an employee at a medical equipment manufacturing facility was training a new coworker how to use the Kobe Machinery Silicone Mill, Serial Number 790181. As the employee reached into the mill to remove a piece of silicone his right hand became lodged between the rollers, degloving the skin of his hand. At this time, the pressure-sensitive safety body bar stopped the mill. The employee was hospitalized for treatment of the hand avulsion.
Keywords: Avulsion, Degloving, Finger, Hand, Machine operator, Milling Machine, Nip Point, Roller--Mach/Part
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1561040.015 | 32 | M | Hospitalized injury | Occupation Not Listed |