Powered by GoogleTranslate

Inspection Detail

Case Status: OPEN

Note: The following inspection has not been indicated as closed. OSHA citation items will be posted 30 (thirty) days after the employer receives the citation(s), except in cases of significant public interest. Posted citation items reflect any amendments to citations that are the result of a prompt settlement, which OSHA encourages. Employers and employee representatives will continue to receive copies of the citation(s) upon issuance.

Inspection: 1558924.015 - Type 7 Manufacturing, Inc.

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 1558924.015
Report ID: 0950614
Date Opened: 10/20/2021

Site Address:
Type 7 Manufacturing, Inc.
2537 Willow Street
Oakland, CA 94607

Mailing Address:
637 Cedar Street, Berkeley, CA 94710

Union Status: NonUnion

SIC:

NAICS: 339999/All Other Miscellaneous Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/17/2022

Emphasis:

Case Closed:


Related Activity
Type Activity Nr Safety Health
Accident 1823643
Case Status: OPEN
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $16,000 $0 $21,600 $0 $0 $37,600
Current Penalty $14,850 $0 $0 $0 $0 $14,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3314(C) 02/22/2022 $10,800 $16,000 $0 I - Informal Settlement  
2. 02001 Serious 3314(G)(2)(A) 02/22/2022 $4,050 $21,600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 140332.015
Event: 10/12/2021
Employee Sustains Face and Neck Fractures When Struck By Com

At 12:00 p.m. on October 12, 2021, an employee was tightening the clamp bolt/nut of a pressurized butane cylinder 6 inch head cap for a Precision Extraction Solutions, Model X10 REV2020, Serial Number 201030065047 cannabis extractor. The equipment pressure at the time was 70 psi and the employee did not depressurize the butane cylinder by closing the Dewax Valve A to stop the flow of butane into the material column. When the employee was tightening the nut, the threads of the bolt securing the clamp unexpectedly failed, causing the head cap of the cylinder to fly upwards, striking the employee in the neck and face. The employee sustained bilateral maxillary and right zygomatic bone fractures and was hospitalized for ten days for surgery and treatment.

Keywords: Bolt, Butane, Clamp, Compressed Gas, Cylinder, Face, Fracture, High Pressure, Neck, Pressure, Projectile, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1558924.015 30 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close