Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1556215.015 - Dynacast, Llc

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 1556215.015
Report ID: 0950631
Date Opened: 10/04/2021

Site Address:
Dynacast, Llc
25952 Commercentre Drive
Lake Forest, CA 92630

Mailing Address:
25952 Commercentre Drive, Lake Forest, CA 92630

Union Status: NonUnion

SIC:

NAICS: 333514/ Special Die and Tool, Die Set, Jig, and Fixture Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/02/2022

Emphasis:

Case Closed: 11/08/2022


Related Activity
Type Activity Nr Safety Health
Accident 1819802
Inspection 1556223 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1 2
Initial Penalty $22,500 $0 $0 $0 $0 $22,500
Current Penalty $9,560 $0 $0 $1,060 $0 $10,620
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4202(A) 03/04/2022 $1,060 $11,250 $0 04/04/2022 O - Administrative Law Judge Order  
2. 02001 Serious 4206(A) 03/04/2022 $9,560 $11,250 $0 04/04/2022 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 144059.015
Event: 09/08/2021
Employee punctures, cuts finger when caught in leak test mac

At 2:15 a.m. on September 8, 2021, an employee was working as a temporary employee at an aluminum components die casting manufacturer. The employee was employed by a staffing agency and was working as a packer at the site. The employee was calibrating a APTIV Model #9242099 Leak Testing Machine prior to testing the actual parts. As a packer, she was assigned to conduct a leak test of each individual component. The leak test machine requires calibration at the beginning of the shift. The employee put the rabbit (testing piece) into the machine and pressed the reset button. She then immediately pressed the cycle start (palm buttons) and the machine cycled. She then reached into the machine and the clamp attached to the pneumatic cylinders caught her left index finger. A coworker, who was her supervisor was on the floor, did not witness the accident. The employee received medical treatment without hospitalization for a puncture wound and laceration to the finger.

Keywords: Aluminum Processing, Catch Point, Clamp, Finger, Hand, Inspecting, Inspection, Laceration, Machine Guarding, Manufacturing, Metal, Misjudgment, Misjudgment of Hazardous Situation, Pinch Point, Pinched, Pneumatic cylinder, Pneumatic equipment, Production Line, Puncture, Puncture Wound, Reaching In, Staffing Agency, Struck By, Temporary, Temporary Employment Agency, Temporary Worker, Unsafe Position

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1556215.015 32 F Non Hospitalized injury Compressing and compacting machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.